Controller
___________________________________________________________________________________
- 306 -
c. TIMER Display
TIMER is used to display the time of TIMER ON and TIMER OFF. The unit symbol Hr will
be ON at the same time.
d. ERROR code display
ERROR is used to display malfunction warning data of the air-conditioner or the CCM.
The display range of ERROR code is E0-EF, where, E means ERROR; 0-F means ERROR code, or
Network ERROR display 00-0F#. If no EEROR, then display “E-“and will be ON.
e. PROTECT. Code display
PROTECT. Is used to display malfunction warning data of the air-conditioner or the CCM.
The display range of PROTECT. Code is P0-PF, where, P means PROTECT, 0-F means PROTECT.
Code. If no PROTECT, then display “P-“and will be ON.
f. ADDRESS display
ADDRESS is used to display the ADDRESS code of the present selected air-conditioner.
The display range is 0-63, and at the same time will be ON.
g. Number Display of Online air-conditioners and ON/OFF air-conditioners
It is used to display the number of online air-conditioners in LAN and ON/OFF air-
conditioners at present. The display range is 0-64.
h. Auxiliary function display
Means ECONOMIC RUNNING, means SWING, means Auxiliary Heater,
means VENT.
i. Mode Confliction Display
Function Confliction display will flash at interval 1 second.
3) Stand-by Page Display
Stand-by page data consist of several pages and the page number is not fixed.
Stand-by page can display the total number of air-conditioners in network, under ON state
and under OFF state. If one or more air-conditioners in network have malfunction, or the CCM
checks other malfunctions, the Stand-by page will display the first ERROR Code from small to
big according to the number. Other malfunctions can be queried by buttons “+” and “-“. If no
malfunction and one or more online air-conditioners in network are in ON state, the Stand-by
page will display present main Running Mode, Set Temp. And Indoor Fan Speed. If no
malfunction and all air-conditioners in network are in OFF state, ERROR Code nor Running mode
will not be displayed.
4) Query Page Display
Query Page data consist of several pages and the page number is not fixed.
a. When first entering into Query Page Display, the address of the first online air-conditioner
will be selected in default and the data of the first page will be displayed.
b. The data of other pages can be displayed in circulation by pressing buttons “+” or “-”.
Page view 306
1 2 ... 302 303 304 305 306 307 308 309 310 311 312 ... 384 385

Comments to this Manuals

No comments