271457-YTG-B-0908
14 Johnson Controls Unitary Products
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - Upflow Furnace Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
47°F17°FHSPF
MBH COP KW MBH COP KW STD
YZB01811
FC/MC/PC/UC18 18.0 3.28 1.61 11.6 2.32 1.46 8.00
HC24 18.0 3.28 1.61 11.6 2.32 1.46 8.00
HD24 18.0 3.28 1.61 11.6 2.32 1.46 8.00
YZB02411
FC/MC/PC/UC24 24.0 3.44 2.04 14.2 2.38 1.75 8.00
FC/MC/PC/UC30 24.0 3.44 2.04 14.2 2.38 1.75 8.00
HC30 24.03.442.0414.22.381.758.00
HD24 24.03.442.0414.22.381.758.00
YZB03011
FC/MC/PC/UC36 30.0 3.44 2.56 18.3 2.28 2.35 8.00
HC36 30.03.442.5618.32.282.358.00
HD36 30.03.442.5618.32.282.358.00
YZB03611
FC/MC/PC/UC36 36.0 3.36 3.14 24.4 2.32 3.08 8.00
HC36 36.03.363.1424.42.323.088.00
HD36 36.03.363.1424.42.323.088.00
YZB04211
FC/MC/PC/UC48 42.0 3.66 3.36 28.4 2.54 3.28 8.00
HC48 42.03.663.3628.42.543.288.00
HD48 42.03.663.3628.42.543.288.00
YZB04811
FC/MC/PC/UC60 48.0 3.50 4.10 33.2 2.30 4.23 8.00
HC60 48.03.504.1033.22.304.238.00
HD60 48.03.504.1033.22.304.238.00
MC61 48.03.504.1033.22.304.238.00
YZB06012 FC/MC62D 57.0 3.54 4.77 37.0 2.44 4.49 8.55
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.