271457-YTG-B-0908
16 Johnson Controls Unitary Products
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
HEATING CAPACITY - YZB02411With Variable Speed Furnaces
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47°F17°FHSPF
MBH COP KW MBH COP KW STD
1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES
PV8*A12 FC/MC/PC24A 23.43.441.9914.22.381.758.00
PV9*A12 FC/MC/PC24A 23.43.621.8913.72.501.618.40
PV8*A12 FC/MC/PC30A 23.43.441.9914.22.381.758.00
PV9*A12 FC/MC/PC30A 23.43.621.8913.72.501.618.40
PV8*A12 HC30 23.43.441.9914.22.381.758.00
PV8*A12 HD24 23.43.441.9914.22.381.758.00
Y*(8,L)C*A12 FC/MC/PC24A 23.6 3.72 1.86 14.2 2.58 1.61 8.20
Y*(8,L)C*B12 FC/MC/PC24B 23.4 3.76 1.82 14.2 2.60 1.60 8.30
Y*9C*B12 FC/MC/PC24B 23.6 3.72 1.86 14.2 2.58 1.61 8.20
Y*(8,L)C*A12 FC/MC/PC30A 23.6 3.72 1.86 14.2 2.58 1.61 8.20
Y*(8,L)C*B12 FC/MC/PC30B 23.4 3.76 1.82 14.2 2.60 1.60 8.30
Y*9C*B12 FC/MC/PC30B 23.6 3.72 1.86 14.2 2.58 1.61 8.20
Y*(8,L)C*A12 FC/MC/PC32A 23.6 3.68 1.88 14.2 2.56 1.63 8.20
Y*(8,L)C*A12 HC30 23.6 3.58 1.93 14.3 2.48 1.69 8.20
Y*(8,L)C*A12 HD24 23.6 3.58 1.93 14.0 2.46 1.67 8.30
Y*(8,L)C*B12 HD24 23.4 3.62 1.89 14.0 2.48 1.65 8.30
Y*9C*B12 HD24 23.6 3.58 1.93 14.0 2.46 1.67 8.30
Y*(8,L)C*A12 UC24A 23.6 3.76 1.84 14.1 2.60 1.59 8.20
Y*(8,L)C*B12 UC24B 23.4 3.80 1.80 14.1 2.62 1.58 8.30
Y*9C*B12 UC24B 23.6 3.76 1.84 14.1 2.60 1.59 8.20
Y*(8,L)C*A12 UC30A 23.6 3.76 1.84 14.1 2.60 1.59 8.20
Y*(8,L)C*B12 UC30B 23.4 3.80 1.80 14.1 2.62 1.58 8.30
Y*9C*B12 UC30B 23.6 3.76 1.84 14.1 2.60 1.59 8.20
G*9V*A12 FC/MC/PC24A 23.6 3.66 1.89 13.9 2.52 1.62 8.20
G*9V*B12 FC/MC/PC24B 23.6 3.72 1.86 14.2 2.58 1.61 8.20
G*9V*A12 FC/MC/PC30A 23.6 3.66 1.89 13.9 2.52 1.62 8.20
G*9V*B12 FC/MC/PC30B 23.6 3.72 1.86 14.2 2.58 1.61 8.20
G*9V*A12 FC/MC/PC32A 23.6 3.64 1.90 14.3 2.52 1.66 8.10
G*9V*A12 HC30 23.6 3.60 1.92 13.8 2.48 1.63 8.20
G*9V*A12 HD24 23.6 3.54 1.95 13.8 2.42 1.67 8.20
G*9V*B12 HD24 23.6 3.58 1.93 14.0 2.46 1.67 8.30
G*9V*A12 UC24A 23.6 3.70 1.87 14.2 2.58 1.61 8.20
G*9V*B12 UC24B 23.6 3.76 1.84 14.1 2.60 1.59 8.20
G*9V*A12 UC30A 23.6 3.70 1.87 14.2 2.58 1.61 8.20
G*9V*B12 UC30B 23.6 3.76 1.84 14.1 2.60 1.59 8.20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.