Page view 31
271457-YTG-B-0908
32 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YZB01811
INDOOR COIL MODEL NO. FC/MC/PC/UC18
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
450 600 750
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 22.9 1.8 3.7 23.7 1.6 4.3 24.4 1.4 5.0
70 21.5 2.0 3.1 22.3 1.8 3.6 23.1 1.6 4.2
80 20.2 2.2 2.6 21.0 2.0 3.0 21.8 1.8 3.6
47
60 20.9 1.8 3.4 21.5 1.6 3.9 22.2 1.4 4.6
70 19.4 2.0 2.9 20.0 1.8 3.3 20.6 1.6 3.7
80 17.9 2.1 2.5 18.5 2.0 2.7 19.0 1.8 3.1
40
60 18.7 1.6 3.3 19.4 1.5 3.7 20.1 1.4 4.2
70 17.0 1.8 2.8 17.8 1.7 3.1 18.7 1.6 3.5
80 15.3 1.9 2.4 16.3 1.8 2.6 17.2 1.7 2.9
30
60 15.8 1.4 3.4 16.7 1.3 3.7 17.6 1.3 4.1
70 14.1 1.5 2.7 14.8 1.4 3.0 15.6 1.4 3.3
80 12.3 1.7 2.2 13.0 1.6 2.4 13.6 1.5 2.7
17
60 12.5 1.4 2.6 13.3 1.3 2.9 14.1 1.3 3.2
70 10.7 1.5 2.1 11.6 1.5 2.3 12.5 1.4 2.6
80 9.0 1.6 1.6 9.9 1.6 1.8 10.8 1.5 2.1
10
60 11.5 1.4 2.4 12.0 1.4 2.6 12.5 1.3 2.8
70 10.0 1.5 1.9 10.5 1.5 2.1 10.9 1.4 2.2
80 8.6 1.7 1.5 8.9 1.6 1.6 9.2 1.6 1.7
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil MBH KW COP
MA08B FC/MC18B 1.00 0.90 1.00
MV12B FC/MC18B 1.00 0.85 1.05
AHP18 1.00 0.90 1.00
AV24 1.00 0.86 1.04
F*FP024 1.00 0.99 1.01
HC24 1.00 0.89 1.00
HD24 1.00 0.89 1.00
Variable Speed
Furnace
Coil MBH KW COP
PV8*A12 FC/MC/PC18A 1.00 0.85 1.05
PV9*A12 FC/MC/PC18A 1.00 0.86 1.04
P(C,V)9*B12 FC/MC/PC18B 1.00 0.85 1.05
Y*(8,L)C*A12 FC/MC/PC18A 0.97 1.07 0.91
Y*(8,L)C*B12 FC/MC/PC18B 0.97 1.05 0.92
Y*9C*B12 FC/MC/PC18B 0.97 1.07 0.91
Y*(8,L)C*A12 FC/MC/PC24A 0.98 1.13 0.87
Y*(8,L)C*B12 FC/MC/PC24B 0.97 1.11 0.88
Y*9C*B12 FC/MC/PC24B 0.98 1.14 0.86
Y*(8,L)C*A12 FC/MC/PC30A 0.98 1.13 0.87
Y*(8,L)C*B12 FC/MC/PC30B 0.97 1.11 0.88
Y*9C*B12 FC/MC/PC30B 0.98 1.14 0.86
Y*(8,L)C*A12 HC18 0.97 1.07 0.91
Y*(8,L)C*A12 HD24 0.98 1.06 0.92
Y*(8,L)C*B12 HD24 0.97 1.02 0.95
Y*9C*B12 HD24 0.97 1.07 0.92
Y*(8,L)C*A12 UC18A 0.98 1.09 0.90
Y*(8,L)C*B12 UC18B 0.97 1.07 0.91
Y*9C*B12 UC18B 0.98 1.09 0.89
Y*(8,L)C*A12 UC24A 0.98 1.14 0.86
Y*(8,L)C*B12 UC24B 0.97 1.12 0.87
Y*9C*B12 UC24B 0.98 1.15 0.85
Y*(8,L)C*A12 UC30A 0.98 1.14 0.86
Y*(8,L)C*B12 UC30B 0.97 1.12 0.87
Y*9C*B12 UC30B 0.98 1.15 0.85
G*9V*A12 FC/MC/PC18A 0.98 1.06 0.92
G*9V*B12 FC/MC/PC18B 0.97 1.07 0.91
G*9V*A12 FC/MC/PC24A 0.98 1.11 0.88
G*9V*B12 FC/MC/PC24B 0.98 1.14 0.86
G*9V*A12 FC/MC/PC30A 0.98 1.11 0.88
G*9V*B12 FC/MC/PC30B 0.98 1.14 0.86
G*9V*A12 HC18 0.98 1.06 0.92
G*9V*A12 HD24 0.98 1.04 0.94
G*9V*B12 HD24 0.97 1.07 0.92
G*9V*A12 UC18A 0.98 1.08 0.91
G*9V*B12 UC18B 0.98 1.09 0.89
G*9V*B12 UC24B 0.98 1.15 0.85
G*9V*A12 UC30A 0.98 1.12 0.88
G*9V*B12 UC30B 0.98 1.15 0.85
Variable Speed
Furnace
Coil MBH KW COP