Wiring
Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.
Remark: All the wiring must be based on the wiring nameplate which shown on the model.
Perform the wiring with sufcient capacity. Installation places legally require a short circuit isolator to be attached to
prevent electrical shock.
Do not extend the power cable code by cutting.
Power voltage should in the range of 90%~110% of rated voltage.
The plug of the air conditioner takes a grounding leg, so clients should use a grounding socket so that the air conditioner
can be grounded efciently.
If the power cord is damaged, replacement should be conducted by quali ed technician or a serviceman.
Note Remark per EMC Directive 89/336/EEC
To prevent icker impressions during the start of the compressor (technical process), following installation conditions do apply.
1.The power connection for the air conditioner has to be done at the main power distribution.
The distribution has to be of an low impedance, normally the required impedance reaches at a 32 A fusing point.
2.No other equipment has to be connected with this power line.
3.For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for
products like washing machines, air conditioner or electrical ovens.
4.For power details of the air conditioner, refer to the rating plate of the product.
5.For any question contact your local dealer.
Cautions
Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.
Connect the connecting cable correctly and connect the connecting cable to terminal as identied with their respective marks.
Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the
surface of cables.
Electrical Connections
All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheeted cord (245 IEC 57 or H05RN-F).
Disconnecting device must have a contact separation of at least 3 mm.
NOTE
CAUTIONS
CAUTIONS
J435.indd 12 1/22/08 11:13:59 AM
Power supply
BLUE
BROWN
BLACK
Y/G
INDOOR UNIT
TO OUTDOOR UNIT
TRANSFORMER
CN10
CN7
CN11
CN8
CN9
CN4
CN5
PIPE TEMPERATURE SENSOR
COMPRESSOR RELAY
CURRENT DETECTOR
DISPLAY BOARD
ROOM TEMPERATURE SENSOR
CN1
CN12
INDOOR MOTOR
STEP MOTOR
Indoor Unit : HTCA12OSAAAR-I
Outdoor Unit : HTCA12OSAAAR-I
1 2(N)
TO INDOOR UNIT
OUTDOOR UNIT
YELLOW/GREEN
OVERLOAD
RELAY
(INTERNAL/
EXTERNAL
DEPENDING
ON MODELS)
COMPRESSON
YELLOW/GREEN
BLACK
BLACK
BLACK
RED
RED
RED
RED
BLUE
BLUE
FAN
COMPRESSON
CAPACITON
FAN CAPACITION