501055-UIM-B-1009
R-410A
OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS: 18 SEER - YZH, HC8B, HL8B SERIES
2 TO 5 TONS
INSTALLATION MANUAL
LISTED
ISO 9001
Certified Quality
Management System
TABLE OF CONTENTS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SECTION IV: TXV INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . .6
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
LIST OF FIGURES
Typical Installation with Required Clearances . . . . . . . . . . . . . . . . . . .3
Tubing Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Typical Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Communications Harness Connection . . . . . . . . . . . . . . . . . . . . . . . . .6
CFM Selection Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Communicating HP with Communicating Air Handler or Furnace . . . .7
Communicating HP with Non-Communicating Air Handler or
Furnace using Communicating Interface Control . . . . . . . . . . . . . . . . .7
Thermostat Wiring – Two-Stage Heat Pumps -
Two-Stage Variable Speed Furnaces . . . . . . . . . . . . . . . . . . . . . . . . .8
Thermostat Wiring – Two-Stage Heat Pumps -
Two-Stage Variable Speed Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermostat Wiring – Two-Stage Heat Pumps -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Thermostat Wiring – Two-Stage Heat Pumps -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Thermostat Wiring – Two-Stage Heat Pumps -
Variable Speed Modulating Furnaces . . . . . . . . . . . . . . . . . . . . . . . . 12
Thermostat Wiring – Two-Stage Heat Pumps -
Variable Speed Modulating Furnaces . . . . . . . . . . . . . . . . . . . . . . . . 13
Heat Pump Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
LIST OF TABLES
Defrost Initiate Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for the smallest rated indoor coil plus 15 feet of field
supplied lines.
Matching indoor coils are available with a thermal expansion valve or
an orifice liquid feed sized for the most common usage. The orifice size
and/or refrigerant charge may need to be changed for some indoor-out-
door unit combinations, elevation differences or total line lengths. Refer
to Application Data covering “General Piping Recommendations and
Refrigerant Line Length” (Part Number 247077).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury
. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
R-410A systems operate at higher pressures than R-22 systems.
Do not use R-22 service equipment or components on R-410A
equipment. Service equipment
Must Be Rated for R-410A.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - INSTALLATION MANUAL

501055-UIM-B-1009R-410AOUTDOOR SPLIT-SYSTEM HEAT PUMPMODELS: 18 SEER - YZH, HC8B, HL8B SERIES2 TO 5 TONSINSTALLATION MANUALLISTEDISO 9001Certified Qua

Page 2

501055-UIM-B-100910 Johnson Controls Unitary Products FIGURE 12: Thermostat Wiring – Two-Stage Heat Pumps - Variable Speed Air HandlerHP 27A Two Stage

Page 3 - MUST BE WEATHERPROOF

501055-UIM-B-1009Johnson Controls Unitary Products 11 FIGURE 13: Thermostat Wiring – Two-Stage Heat Pumps - Variable Speed Air HandlerHP 27C Two Stage

Page 4

501055-UIM-B-100912 Johnson Controls Unitary Products FIGURE 14: Thermostat Wiring – Two-Stage Heat Pumps - Variable Speed Modulating FurnacesHP 28A T

Page 5 - INSTALLATIONS

501055-UIM-B-1009Johnson Controls Unitary Products 13 FIGURE 15: Thermostat Wiring – Two-Stage Heat Pumps - Variable Speed Modulating FurnacesHP 28C T

Page 6

501055-UIM-B-100914 Johnson Controls Unitary ProductsSECTION VI: EVACUATIONIt will be necessary to evacuate the system to 500 microns or less. If alea

Page 7 - CFM SELECTION BOARD SETTINGS

501055-UIM-B-1009Johnson Controls Unitary Products 15SECTION VIII: SYSTEM OPERATIONFor more information on the control operation, refer to “OperationI

Page 8

Subject to change without notice. Published in U.S.A. 501055-UIM-B-1009Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 501

Page 9

501055-UIM-B-10092 Johnson Controls Unitary ProductsINSPECTIONAs soon as a unit is received, it should be inspected for possible dam-age during transi

Page 10 - 501055-UIM-B-1009

501055-UIM-B-1009Johnson Controls Unitary Products 3GROUND INSTALLATIONThe unit may be installed at ground level on a solid base that will notshift or

Page 11

501055-UIM-B-10094 Johnson Controls Unitary ProductsPRECAUTIONS DURING LINE INSTALLATION1. Install the lines with as few bends as possible. Care must

Page 12

501055-UIM-B-1009Johnson Controls Unitary Products 55. Slide the grommet away from the vapor connection at the indoorcoil. Braze the vapor line to the

Page 13

501055-UIM-B-10096 Johnson Controls Unitary ProductsFIELD CONNECTIONS POWER WIRING1. Install the proper size weatherproof disconnect switch outdoors a

Page 14 - SECTION VII: SYSTEM CHARGE

501055-UIM-B-1009Johnson Controls Unitary Products 7DEHUMIDIFICATION CONTROLA dehumidification control accessory 2HU06700124 may be used withvariable

Page 15

501055-UIM-B-10098 Johnson Controls Unitary Products FIGURE 10: Thermostat Wiring – Two-Stage Heat Pumps - Two-Stage Variable Speed FurnacesHP 24A Two

Page 16 - SECTION X: WIRING DIAGRAM

501055-UIM-B-1009Johnson Controls Unitary Products 9 FIGURE 11: Thermostat Wiring – Two-Stage Heat Pumps - Two-Stage Variable Speed FurnacesHP 24C Two