NORMAL FUNCTION OF THE AIR CONDITIONER
The following symptoms do not indicate air conditioner malfunction.
1. The system does not operate
The system does not restart immediately
after the ON/OFF button is pressed.
If the OPERATION lamp lights, the system is
in normal condition.
The safety device operates to prevent overload of the system.
After 3 minutes, the system will turn on again automatically.
The system does not restart immediately when
TEMPERATURE SETTING changed.
If the OPERATION lamp lights, the system is in normal condition.
If the timer light is flashing operation is being delayed by the safety
device. It does not restart immediately because the compressor
has been stopped and requested to start within the delay period.
A safety device operates to prevent overload of the system.
After 3 minutes, the system will turn on again automatically.
The system does not start immediately after the power supply is turned on.
Wait one minute until the microcomputer is prepared for operation.
1.1
White mist comes out of a unit
When humidity is high during cooling operation.
(In dusty locations or after construction work)
If the inside of an indoor unit is contaminated,
the temperature distribution inside a room may
become uneven. It is necessary to clean the inside
of the indoor unit. The unit should be cleaned by
a quali fied service person familiar with the unit.
When the system is changed over to HEATING OPERATION
or after DEFROST OPERATION. Moisture generated on
the coil by the DEFROST becomes vapour and exists.
1.2 Noise of air conditioners
A continuous flow “Shuh” sound is heard when the systems is in COOLING
or DEFROST OPERATION. This is the sound of refrigerant
gas flowing through both indoor and outdoor units.
A “Shuh” sound which is heard at the start or
immediately after operation. It may also be heard
at the start or immediately after a DEFROST OPERATION.
This is the noise of refrigerant caused by the start and stop of the flow.
A “Pishi-pishi” squeaking sound is heard when the system is in
operation or just after operation. Expansion and contraction of plastic
parts caused by temperature change makes this noise.
1.3
Dust from the units
Dust may blow out from the unit when starting after long off cycles.
Dust absorbed by the unit blows out.
The units give off odours. The unit absorbs the smell of rooms,
furniture, cigarettes, etc., and then emits them.
EMERGENCY OPERATION
Units are equipped with a switch to run
emergency operation mode. Pushing the
emergency switch turns the unit on;
pushing it again turns if off (toggle action).
During emergency operation, the remote
controller cannot be used and the power
LED light will flash at intervals, while the
other LED lights will indicate the operation
of the Diagnostic Codes.
In Emergency Operation and cooling units
the temperature will be set at 24°C and the fan on Auto.
Heating units will switch to auto mode at a temperature set
point of 24°C and the fan will run on auto mode.
After a power failure the unit restarts automatically in the same
mode as before the failure, when power is resumed.
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
Floor/Ceiling YOHC (YOKC-YOJC)R-410A 50Hz Rev.291106
PROTECTION FUNCTION
Auto Restart Function
The unit will automatically restart after loss of the electrical power supply. When power is
restored;
the unit operation will restart according to all parameters set before the loss of
powe
r.
ANTI-ICE and
ANTI-OVERHEAT
This feature is used to prevent the indoor unit from freezing during cool or dry operation
and
overheating in heat mode. During execution of anti-ice operation and anti-overheating,
the
compressor will stop operating and the fan will continue to run until the coil temperature
reaches predetermined set points, at which time the unit will resume normal operation.
Low
Voltage
The feature is used to protect against any damage to the unit caused by fluctuation of voltage.
If
voltage is lower than the lower limit for approximately 10 seconds or longer, compressor
operation
will be temporarily stopped. Normal operation will resume when the voltage returns
abo
ve the set limit for a minimum of 10 seconds. If the time elapsed is less than 3 minutes
then the compressor start up will be delayed until 3 minutes has passed.
Filter Care and Filter
Alarm
Replace Air Purifying filter if fitted.
The filters should be cleaned regularly, i.e, once a month, or more frequently depending on
conditions.
The control is equipped with a filter alarm; After a certain numbers of hours of
operation, flashing
lights will indicate that it is time to clean the filter. The alarm is reset by
pressing the filter button or the transmitte
r.
MAINTENANCE
The units are designed to operate for long periods of time with a minimum of maintenance.
Howeve
r, the following operation must be performed regularly.
* This operation must be carried out by quali fied personnel only.
BEFORE MAINTENANCE
S Turn off the main breaker or disconnect the main power supply.
Notes
• Don’t spill water : There is a danger of electric shock.
• Don’t used petrol, paint thinner, benzene or polishing agents
: They may deform or scratch the unit.
CLEANING THE UNIT
Wipe the unit with a soft dry cloth only.
If the unit is very dirty, wipe it with a cloth soaked
in warm water (Not more than 40°C).
CLEANING THE AIR FILTER
1. Remove the air filter.
Open front grille
and pull fillter
outward front grille.
3. Drying
Drying the air filter by hair
drying or direct sunlight.
2. Cleaning
If the fillter is very dirty,
clean it with water
(approx 30°C).
4. Reinstall the air filter.
Approx 30 °C
EMERGENCY
OPER
ATION
Not more than
40°C
Remark: The above design and specifications are subject to change without prior notice for product improvement.
Floor/Ceiling YOCC (YOEC-YODC) COOLING R-410A 50Hz Rev.291106
Maintenance Operations Recommended Frequency
Air filter Clean Every month or more often if necessary
Unit casing Clean Every month or more often if necessary
Drain pan and evacuation piping Clean and check for obstructions Each season before start up*
Indoor/outdoor coils Clean Each season before start up*
Compressor No need
Model
Set YOHC18DSBAAR YOHC24DSBAAR YOHC36DSBACR YOHC48DSBACR YOHC60DSBACR
Indoor YOKC18DS-BAR YOKC24DS-BAR YOKC36DS-BCR YOKC48DS-BCR YOKC60DS-BCR
Outdoor YOJC18DS-BAR YOJC24DS-BAR YOJC36DS-BCR YOJC48DS-BCR YOJC60DS-BCR
Power supply V-Ph-Hz 220~240-1-50 220~240-1-50 380V~3~ 50Hz 380V~3~ 50Hz 380V~3~ 50Hz
Cooling
Capacity Btu/h 18,000 24,000 36,000 48,000 60,000
Input W 1,550 2,220 3,290 4,300 4,940
Rated current A 6.8 9.25 8.77 11.47 11.47
Heating
Capacity Btu/h 21,000 28,000 40,000 53,000 62,000
Input W 1,680 2,250 3,160 4,170 4,880
Rated current A 7.35 9.4 8.33 10.99 11.4
Max. input consumption W 2,500 2,750 3,880 4,850 5,990
Max. current A 10 11 10.17 12.98 15.69
Starting current A 1.08 1.15 1.1 1.16 1.23
Compressor
Type DC Inverter Rotary DC Inverter Scroll
Input W 1,650 1,650 3,665 3,665 3,665
Rated current (RLA) A 8 8 7.8 7.8 7.8
Locked rotor Amp (LRA) A 28 28 28 28 28
Protector Thermal
Capacitor µF 50 50 50 50 50
Refrigerant oil ml 480 480 500 500 500
Indoor fan motor
Type AC Motor
Input W 110 110 134 89.5 59
Capacitor µF 2.5 2.5 3.5 2.5 2.5
Speed (Hi/Me/Lo) r/min 1,310/1,190/1,020 1,310/1,190/1,020 1,265/1,165/1,075 1,170/1,070/995 1,145*1,035*975
Indoor coil
Number of rows 3 3 3 3 3
Fin spacing mm 1.8 1.8 1.8 1.8 1.8
Fin type Hydrophilic aluminium
Tube outside dia. mm Ø9.52
Tube Material Innergroove tube
Coil length × height × width mm 828×254×66 828×254×66 905×203×66 1150×254×66 1150×254×66
Indoor air flow (Hi/Me/Lo) m
3
/h 910/810/700 910/810/700 1,400/1,200/1,000 2,000/1,800/1,600 2,000/1,800/1,600
Indoor noise level (Hi/Me/Lo) dB(A) 49.5/-/- 53/-/- 45/43/40 47/45/42 47/45/42
Indoor unit
Dimension (W*H*D) mm 980×660×195 980×660×195 1,285×660×198 1,670×680×240 1,670×680×240
Packing (W*H*D) mm 1,089×744×296 1,089×744×296 1,379×744×296 1,764×760×329 1,764×760×329
Net/Gross weight kg 29/35 29/35 37/42 54/61 54/61
Outdoor fan motor
Input W 129 150 307 150*2 150*2
Capacitor µF 3 3 10 3.5*2 3.5*2
Speed r/min 770 800 740 800 800
Outdoor coil
Number of rows 2 2 1 1 1
Fin spacing mm 1.7 1.5 1.7 1.8 1.8
Fin type Hydrophilic aluminium
Tube outside dia. mm Ø9.52
Tube Material Innergroove tube
Coil length × height × width mm 630×660×44 620×813×44 955×915×22 715×610×22 1,150×305×66
Number of circuits 4 2 8 4 4
Outdoor air flow m
3
/h 2,400 3,000 5,000 6,000 6,000
Outdoor noise level dB(A) 56 55 57 58 58
Outdoor unit
Dimension (W*H*D) mm 840×677×310 894×860×302 990×960×340 940×1,245×340 940×1,245×340
Packing (W*H*D) mm 965×770×395 1,043×915×395 1,120×1,015×435 1,058×1,300×435 1,058×1,300×435
Net/Gross weight kg 62.5/66.5 72/76.5 106/111 117/126 112/127
Refrigerant R-410A g 1,650 2,200 2,600 3,550 4,200
Throttle type EXV&Capillary
Refrigerant piping Liquid side/Gas side mm 6.35/12.7 9.53/16 9.53/16 9.53/16 9.53/16
Model
Set YOCC12FSA(B)AAR YOCC18FSA(B)AAR YOCC24FSA(B)AAR YOCC30FSA(B)ACR YOCC30FSA(B)AAR YOCC36FSA(B)AAR YOCC36FSA(B)ACR YOCC48FSA(B)ACR YOCC60FSA(B)ACR
Indoor unit YOEC12FS-A(B)AR YOEC18FS-A(B)AR YOEC24FS-A(B)AR YOEC30FS-A(B)CR YOEC30FS-A(B)AR YOEC36FS-A(B)AR YOEC36FS-A(B)CR YOEC48FS-A(B)CR YOEC60FS-A(B)CR
Outdoor Unit YODC12FS-A(B)AR YODC18FS-A(B)AR YODC24FS-A(B)AR YODC30FS-A(B)CR YODC30FS-A(B)AR YODC36FS-A(B)AR YODC36FS-A(B)CR YODC48FS-A(B)CR YODC60FS-A(B)CR
Power supply Ph-V-Hz 1,220-240V,50Hz 1,220-240V,50Hz 1,220-240V,50Hz 3,380V,50Hz 1,220-240V,50Hz 1,220-240V,50Hz 3,380V,50Hz 3,380V,50Hz 3,380V,50Hz
Cooling
Capacity
Btu/h 12,000 18,000 24,000 30,000 30,000 36,000 36,000 48,000 60,000
kW 3.5 5.4 7.1 9.2 9.2 10.5 10.5 14 17
kcal/h 3,024 4,536 6,048 7,560 7,560 9,072 9,072 12,096 15,120
Input W 1,200 1,900 2,600 3,450 3,450 3,800 3,800 4,900 5,800
Rated current A 5.3 8.5 12.1 6.4 16.4 19.2 6.4 8.2 9.8
Moisture Removal L/h 1.2 1.8 2.4 3 3 3.6 3.8 4.8 6
Max. input consumption W 1,400 2,600 3,300 5,200 5,200 5,200 5,200 6,100 7,200
Max. current A 7.2 13 16.5 8.8 25 26.3 8.8 10.3 12.2
Starting current A 26 36.8 61 97 97 97 61 66 67
Compressor
Type ROTARY ROTARY ROTARY SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL
Input W 1,145 1,870 2,430 3,650 3,650 3,650 3,650 4,750 5,750
Rated current (RLA) A 5.3 8.75 11.4 6.58 17.65 17.65 6.58 8.22 9.77
Locked rotor Amp (LRA) A 26 36.8 61 61 97 97 61 66 67
Thermal protector Inner Inner Inner Inner Inner Inner Inner Inner Inner
Capacitor µF 35/370µF/V 50/370µF/V 50/400µF/V / 60µF/440V 60µF/440V / / /
Indoor fan motor
Input W 104/98 110/104/98 110/104/98 142/134/132 142/134/132 142/134/132 142/134/132 118/108/101 118/108/101
Capacitor µF 1.5µF/450V 2.5µF/450V 2.5µF/450V 3.5µF/450V 3.5µF/450V 3.5µF/450V 3.5µF/450V 2.5µF/450V 2.5µF/450V
Speed (Hi/Mid/Low) r/min 1,190/1,000/890 1,280/1,190/1,000 1,280/1,190/1,000 1,310/1,200/1,000 1,310/1,200/1,000 1,310/1,200/1,000 1,310/1,200/1,000 820/695/620 820/695/620
Indoor coil
Number of rows 2 3 3 3 3 3 3 3 3
Fin spacing mm 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
Fin type Hydrophilic aluminum
Tube outside dia.and type mm Ø9.53 innergroove tube
Coil length × height × width mm 804×254×44 804×254×66 804×254×66 905×203×66 905×203×66 905×203×66 905×203×66 1,150×254×66 1,150×254×66
Indoor air flow (Hi/Mid/Low) m
3
/h 600/480/400 800/600/500 1,000/900/700 1,200/1,000/800 1,400/1,200/1,000 1,400/1,200/1,000 1,400/1,200/1,000 2,000/1,800/1,600 2,000/1,800/1,600
Indoor noise level (Hi/Mid/Low) dB(A) 43/41/38 43/41/38 45/43/40 45/43/40 45/43/40 45/43/40 45/43/40 47/45/42 47/45/42
Indoor unit
Dimension (W*H*D) mm 995×660×198 995×660×198 995×660×198 1,285×660×198 1,285×660×198 1,285×660×198 1,285×660×198 1,670×680×240 1,670×680×240
Packing (W*H*D) mm 1,075×744×278 1,075×744×278 1,075×744×278 1,365×744×278 1,365×744×278 1,365×744×278 1,365×744×278 1,764×760×329 1,764×760×329
Net/Gross weight kg 30/37 30/37 30/37 34/42 34/42 34/42 34/42 52/62 52/62
Outdoor fan
motor
Input W 56 130 130 307 307 307 307 138+156 138+156
Capacitor µF 2.5µF/450V 2.5µF/450V 3µF/450V 10µF/450V 10µF/450V 10µF/450V 10µF/450V 3.5×2µF/450V 3.5×2µF/450V
Speed r/min 800 750 800 740 740 740 740 800 800
Outdoor coil
Number of rows 2 2 2 2 2 2 2 2 2
Fin spacing mm 1.4 1.7 1.5 1.7 1.7 1.7 1.7 1.8 1.8
Fin type Unhydrophilic aluminum
Tube outside dia. and type mm Ø9.53, Innergroove tube
Coil length × height × width mm 651×559×44 775×660×44 850×810×44 955×915×44 955×915×44 955×915×44 955×915×44 715×1,220×44 715×1,220×44
Outdoor air flow m
3
/h 2,100 2,400 3,000 5,000 5,000 5,000 5,000 6,000 6,000
Outdoor noise level dB(A) 43 48 55 57 57 57 57 58 58
Outdoor unit
Dimension (W*H*D) mm 760×590×285 845×695×335 895×860×330 990×960×360 990×960×360 990×960×360 990×960×360 940×1,245×340 940×1,245×340
Packing (W*H*D) mm 887×655×355 970×770×395 1,043×915×395 1,120×1,090×435 1,120×1,090×435 1,120×1,090×435 1,120×1,090×435 1,058×1,380×435 1,058×1,380×435
Net/Gross weight kg 44/48 57/62 68/70 90/102 90/102 90/102 90/102 112/127 112/127
Refrigerant type/Quantity g R-410A/1,100 R-410A/2,000 R-410A/2,600 R-410A/3,000 R-410A/3,000 R-410A/3,000 R-410A/3,000 R-410A/3,700 R-410A/3,900
Design pressure (high side/low side) MPa 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5
Refrigerant
piping
Liquid side mm (inch) 6.35 (1/4) 6.35 (1/4) 9.53 (3/8) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2)
Gas side mm (inch) 12.7 (1/2) 12.7 (1/2) 16 (5/8) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4)
Max. pipe length m 25 25 30 30 30 30 30 50 50
Max. difference in level m 15 15 15 20 20 20 20 30 30
Operation temp ºC 17~30 17~30 17~30 17~30 17~30 17~30 17~30 17~30 17~30
Ambient temp ºC 18~45 18~45 18~45 18~45 18~45 18~45 18~45 18~45 18~45
Qty’per 20’& 40’Fcl Pieces 63/138/155 49/104/126 44/94/101 27/55/62 27/55/62 27/55/62 27/55/62 25/50/54 25/50/54
Model
Set YOHC12FSA(B)AAR YOHC18FSA(B)AAR YOHC24FSA(B)AAR YOHC30FSA(B)ACR YOHC30FSA(B)AAR YOHC36FSA(B)AAR YOHC36FSA(B)ACR YOHC48FSA(B)ACR YOHC60FSA(B)ACR
Indoor unit YOKC12FS-A(B)AR YOKC18FS-A(B)AR YOKC24FS-A(B)AR YOKC30FS-A(B)CR YOKC30FS-A(B)AR YOKC36FS-A(B)AR YOKC36FS-A(B)CR YOKC48FS-A(B)CR YOKC60FS-A(B)CR
Outdoor Unit YOJC12FS-A(B)AR YOJC18FS-A(B)AR YOJC24FS-A(B)AR YOJC30FS-A(B)CR YOJC30FS-A(B)AR YOJC36FS-A(B)AR YOJC36FS-A(B)CR YOJC48FS-A(B)CR YOJC60FS-A(B)CR
Power supply Ph-V-Hz 1,220-240V, 50Hz 1,220-240V, 50Hz 1,220-240V, 50Hz 3,380V, 50Hz 1,220-240V, 50Hz 1,220-240V, 50Hz 3,380V, 50Hz 3,380V, 50Hz 3,380V, 50Hz
Cooling
Capacity
Btu/h 12,000 18,000 24,000 30,000 30,000 36,000 36,000 48,000 60,000
kW 3.5 5.4 7.1 9.2 9.2 10.5 10.5 14 17
kcal/h 3,024 4,536 6,048 7,560 7,560 9,072 9,072 12,096 15,120
Input W 1,200 1,900 2,700 3,750 3,750 3,750 3,750 4,700 6,000
Rated current A 6 8.5 12 6.3 16.3 16.3 6.6 8.2 9.8
Heating
Capacity
Btu/h 13,000 20,500 27,300 32,000 32,000 39,000 39,000 52,000 68,000
kW 3.8 6 8 9.4 9.4 11.4 11.4 15.2 20
kcal/h 3,276 5,166 6,880 8,064 8,064 9,828 9,828 13,104 17,136
Input W 1,130 1,850 2,800 3,500 3,500 3,500 3,700 4,900 6,000
Rated current A 5 8 12.5 5.2 15.2 15.2 6.5 8.6 9.8
Moisture Removal L/h 1.2 1.8 2.4 3 3 3.6 3.8 4.8 6
Max. input consumption W 1,500 2,400 3,300 4,620 4,620 4,620 4,400 5,870 7,500
Max. current A 7 11.5 14.5 7.1 21 21 8 10.7 12.8
Starting current A 26 36.8 61 61 97 97 61 66 67
Compressor
Type ROTARY ROTARY ROTARY SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL
Input W 1,145 1,870 2,430 3,650 3,650 3,650 3,650 4,750 5,750
Rated current (RLA) A 5.3 8.75 11.4 6.58 17.65 17.65 6.58 8.22 9.77
Locked rotor Amp (LRA) A 26 36.8 61 61 97 97 61 66 67
Thermal protector Inner Inner Inner Inner Inner Inner Inner Inner Inner
Capacitor µF 35/370µF/V 50/370µF/V 50/400µF/V / 60µF/440V 60µF/440V / / /
Indoor fan motor
Input W 104/98 110/104/98 110/104/98 142/134/132 142/134/132 142/134/132 142/134/132 118/108/101 118/108/101
Capacitor µF 1.5µF/450V 2.5µF/450V 2.5µF/450V 3.5µF/450V 3.5µF/450V 3.5µF/450V 3.5µF/450V 2.5µF/450V 2.5µF/450V
Speed (Hi/Med/Low) r/min 1,190/1,000/890 1,280/1,190/1,000 1,280/1,190/1,000 1,310/1,200/1,000 1,310/1,200/1,000 1,310/1,200/1,000 1,310/1,200/1,000 820/695/620 820/695/620
Indoor coil
Number of rows 2 3 3 3 3 3 3 3 3
Tube pitch(a) × row pitch(b) mm 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22
Fin spacing mm 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
Fin type Hydrophilic aluminum
Tube outside dia. and type mm Ø9.53 innergroove tube
Coil length × height × width mm 804×254×44 804×254×66 804×254×66 905×203×66 905×203×66 905×203×66 905×203×66 1,150×254×66 1,150×254×66
Indoor air flow (Hi/Mid/Low) m
3
/h 600/480/400 800/600/500 1,000/900/700 1,200/1,000/800 1,400/1,200/1,000 1,400/1,200/1,000 1,400/1,200/1,000 2,000/1,800/1,600 2,000/1,800/1,600
Indoor noise level (Hi/Mid/Lo) dB(A) 43/41/38 43/41/38 45/43/40 45/43/40 45/43/40 45/43/40 45/43/40 47/45/42 47/45/42
Indoor unit
Dimension (W*H*D) mm 995×660×198 995×660×198 995×660×198 1,285×660×198 1,285×660×198 1,285×660×198 1,285×660×198 1,670×680×240 1,670×680×240
Packing (W*H*D) mm 1,075×744×278 1,075×744×278 1,075×744×278 1,365×744×278 1,365×744×278 1,365×744×278 1,365×744×278 1,764×760×329 1,764×760×329
Net/Gross weight kg 29/35 30/37 30/37 34/42 34/42 34/42 34/42 52/62 52/62
Outdoor fan
motor
Input W 56 130 130 307 307 307 307 138+156 138+156
Capacitor µF 2.5µF/450V 2.5µF/450V 3µF/450V 10µF/450V 10µF/450V 10µF/450V 10µF/450V 3.5×2µF/450V 3.5×2µF/450V
Speed r/min 800 750 800 740 740 740 740 800 800
Outdoor coil
Number of rows 2 2 2 2 2 2 2 2 2
Tube pitch(a) × row pitch(b) mm 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22 25.4×22
Fin spacing mm 1.4 1.7 1.5 1.7 1.7 1.7 1.7 1.8 1.8
Fin type Hydrophilic aluminum Unhydrophilic aluminium Hydrophilic aluminum
Tube outside dia. and type mm Ø9.53x0.35,Innergroove tube
Coil length × height × width mm 651×559×44 775×660×44 850×810×44 955×915×44 955×915×44 955×915×44 955×915×44 715×1220×44 715×1220×44
Number of circuits 2 3 4 8 8 8 8 4 4
Outdoor air flow m
3
/h 2,100 2,400 3,000 5,000 5,000 5,000 5,000 6,000 6,000
Outdoor noise level dB(A) 43 48 55 57 57 57 57 58 58
Outdoor unit
Dimension (W*H*D) mm 760×590×285 845×695×335 895×860×330 990×960×360 990×960×360 990×960×360 990×960×360 940×1,245×340 940×1,245×340
Packing (W*H*D) mm 887×655×355 970×770×395 1,043×915×395 1,120×1,090×435 1,120×1,090×435 1,120×1,090×435 1,120×1,090×435 1,058×1,380×435 1,058×1,380×435
Net/Gross weight kg 44/48 57/62 68/70 90/102 90/102 90/102 90/102 112/127 112/127
Refrigerant type/Quantity g R-410A/1,120 R-410A/2,050 R-410A/2,600 R-410A/3,100 R-410A/3,450 R-410A/3,450 R-410A/3,100 R-410A/4,000 R-410A/4,200
Design pressure (high side/low side) MPa 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5 4.2/2.5
Refrigerant
piping
Liquid side mm (inch) 6.35 (1/4) 6.35 (1/4) 9.53 (3/8) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2) 12.7 (1/2)
Gas side mm (inch) 12.7 (1/2) 12.7 (1/2) 16 (5/8) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4) 19 (3/4)
Max. pipe length m 25 25 30 30 30 30 30 50 50
Max. difference in level m 15 15 15 20 20 20 20 30 30
Operation temp ºC 17~30 17~30 17~30 17~30 17~30 17~30 17~30 17~30 17~30
Ambient temp ºC -7~45 -7~45 -7~45 -7~45 -7~45 -7~45 -7~45 -7~45 -7~45
Qty’per 20’& 40’Fcl Pieces 63/138/155 49/104/126 44/94/101 27/55/62 27/55/62 27/55/62 27/55/62 25/50/54 25/50/54
Floor/Ceiling DC Inverter “YOHC” R-410A, 50Hz
J354-EN.indd 4J354-EN.indd 4 4/25/07 5:03:18 PM4/25/07 5:03:18 PM
York Industrial Thailand
49/40 Moo5, Tambon Tungsukla, Sriracha, Chonburi 20230, Thailand.
Tel. +6638 493400 Fax. +6638 493423- 424
Ref No.: 07GMSPG0529DC005-0
Type of Equipment:
Brand Name:
Type Designation: YOCC-YOHC 12/18/24/30/36/48/60 FS
YOHC 18/24/36/48/60 DS
Application of Council: Low Voltage Directive 73/23/EEC, EMC Directive
89/336/EEC, CE Marking
Directive 93/68/EEC and Machinery Directive 98/37/EEC.
The equipments above follow harmonized standards have been applied:
EN 60335-1:1994+A11:1995+A1, A12:1996+A
13, A14:1998+A15, A2:2000+A16:2001
EN 60335-2-40:1997+A1:2000
EN55014-1:2000+A1+A2
EN55014-2:1994+A1
EN61000-3-2:2000
EN61000-3-3:1995+A1
EN61000-3-11:2000
Authorized Representative:
_________________________
Suriya Sittidamrong
Senior Technical Support Engineer
DE - COMMISSIONING DISMANTLING & DISPOSAL
This product contains refrigerant under pressure, rotating parts, and electrical
connections which may be a danger and cause injury!
All work must only be carried out by competent persons using suitable protective
clothing and safety precautions.
1. Isolate all sources of electrical supply to the unit including any control system supplies
switched by the unit. Ensure that all points of electrical and gas isolation are secured in the
OFF position. The supply cables and gas pipework may then be disconnected and removed.
For points of connection refer to unit installation instructions.
2. Remove all refrigerant from each system of the unit into a suitable container using a
refrigerant reclaim or recovery unit. This refrigerant may then be reused, if appropriate, or
returned to the manufacturer for disposal Under No circumstances should refrigerant be
vented to atmosphere. Where appropriate, drain the refrigerant oil from each system into a
suitable container and dispose of according to local laws and regulations governing disposal
of oily wastes.
3. Packaged unit can generally be removed in one piece after disconnection as above. Any
fi
xing down bolts should be removed and then unit lifted from position using the points
provided and equipment of adequate lifting capacity. Reference MUST be made to the unit
installation instructions for unit weight and correct methods of lifting. Note that any residual
or spilt refrigerant oil should be mopped up and disposed of as described above.
4. After removal from position the unit parts may be disposed of according to local laws and
regulations.
Read the Manual
Unit is remotely controlled and
may start without warning
Risk of electric shock
DECLARATION OF CONFORMITY
Date: May 29, 2007
DECLARATION OF CONFORMITY
YORK
Air Conditioners
Page view 3
1 2 3 4

Comments to this Manuals

No comments