8
ENGLISH
OPERATING TEMPERATURE
Mode
Temperature
Cooling operation Heating operation Drying operation
Room temperature 17°C~32°C 0°C~30°C 17°C~30°C
Outdoor temperature 21°C~43°C -7°C~24°C 11°C~43°C
CAUTIONS
1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation
cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the
air conditioner may attract condensation. Please set the vertical air flow louver to its maximum angle (Vertically to
the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Outdoor Unit Multi Inverter RRJC 18-27
Model RRJC 18AA-AAA RRJC 27AA-AAA
Indoor Units Combination Single Double Single Double Treble
Power supply Ph-V-Hz 1Ph, 220-240V~, 50Hz 1Ph, 220-240V~, 50Hz
Cooling
Capacity
Btu/h 7,000~12,000 18,000 7,000~12,000 16,000~24,000 27,000
W 2,050~3,517 5,275 2,000~3,500 4,690~7,000 7,913
Input W 1,000~1,300 1,813 1,000~1,300 2,570~2,850 2,806
Rated current A 4.8~6.5 11.5 4.8~6.5 11.7~13.5 13.5
Heating
Capacity
Btu/h 9,000~14,000 21,000 10,000~14,000 24,000~27,000 30,000
W 2,638~4,103 6,155 2,900~4,100 7,000~7,900 8,792
Input W 1,300~1,600 2,038 1,300~1,600 2,100~2,750 2,739
Rated current A 6.3~7.8 11.0 6.3~7.8 11.0~13.2 13.2
Max. input W 3,200 3,200
Max. current A 20 20
Compressor
Type
Rotary inverter Rotary inverter
Input W 1,690 1,690
Rated current (RLA) A 11.6 11.6
Locked rotor Amp (LRA)
A 60 60
Thermal protector Internal Internal
Capacitor µF 85µF/250V 85µF/250V
Refrigerant oil ml 750 750
Outdoor fan
motor
Input W 148 148
Capacitor µF 3 3
Speed r/min 775 775
Outdoor coil
Number of rows 2 2
Fin spacing mm 1.7 1.7
Fin type Hydrophilic aluminium Hydrophilic aluminium
Tube outside dia.
mm Ø9.53 Ø9.53
Tube Material
Innergroove tube Innergroove tube
Coil length x height x width mm 776×660×22 776×660×22
Number of circuits 2 2
Outdoor air flow
m
3
/h 2,500 2,500
Outdoor noise level dB(A) 60 60
Outdoor
unit
Dimension (WxHxD) mm 845X695X335 845X695X335
Packing (WxHxD) mm 965X772X405 965X772X405
Net/Gross weight kg 71/74 72/76
Refrigerant Type R-410A
g 2,100 2,250
Refrigerant
piping
Liquid side/ Gas side mm Ø6.35/Ø9.53 3 X Ø6.35/Ø9.53
Transfer Connector (9.5312.7) mm 2 2
Max. refrigerant pipe length m 15 (each indoor unit) 15 (each indoor unit)
Max. difference in level m 10 (each indoor unit) 10 (each indoor unit)
Remark : The above design and specifications are subject to change without prior notice for product improvement.
J368-EN.indd 8 2/1/07 9:40:57 AM