York 090 User Manual

Browse online or download User Manual for Pumps York 090. York 090 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
279104-YTG-B-0307
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
SPLIT-SYSTEM HEAT PUMPS
10 SEER – R-22
MODELS:
E*RA036 THRU 060
(3 THRU 5 NOMINAL TONS, 3 PH)
MODELS: 036-048 (3 PH)
MODELS: 060, 090 (3 PH)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory.
LISTED
ISO 9001
Certified Quality
Management System
DESCRIPTION
The 10 SEER Series heat pumps is the outdoor part of a ver-
satile system of heat pumps. It is designed to be custom-
matched with one of UPG’s complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
1-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY COILS - The coil is constructed of copper tube
and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the con-
denser fan make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - FEATURES

279104-YTG-B-0307FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDESPLIT-SYSTEM HEAT PUMPS10 SEER – R-22MODELS:E*RA03

Page 2 - Physical and Electrical Data

279104-YTG-B-030710 Unitary Products GroupMultipliers for determining the performance with other indoor sections.NOTE: For dry bulb temperatures diffe

Page 3

279104-YTG-B-0307Unitary Products Group 11Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb temperatures diff

Page 4 - 4 Unitary Products Group

279104-YTG-B-030712 Unitary Products GroupMultipliers for determining the performance with other indoor sections.HEATING PERFORMANCE DATACONDENSING UN

Page 5

279104-YTG-B-0307Unitary Products Group 13Multipliers for determining the performance with other indoor sections.HEATING PERFORMANCE DATACONDENSING U

Page 6 - 6 Unitary Products Group

279104-YTG-B-030714 Unitary Products GroupMultipliers for determining the performance with other indoor sections.HEATING PERFORMANCE DATACONDENSING UN

Page 7 - TYPICAL INSTALLATION

279104-YTG-B-0307Unitary Products Group 15NOTES

Page 8 - 8 Unitary Products Group

Subject to change without notice. Printed in U.S.A. 279104-YTG-B-0307Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 27

Page 9

279104-YTG-B-03072 Unitary Products GroupAll dimensions are in inches. They are subject to changewithout notice. Certified dimensions will be provided

Page 10 - COOLING PERFORMANCE DATA

279104-YTG-B-0307Unitary Products Group 3PROCEDURES:1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the s

Page 11 - 279104-YTG-B-0307

279104-YTG-B-03074 Unitary Products Group- = Not applicableCOOLING CAPACITY - With Air Handler CoilsUNIT MODELAIR HANDLERCOIL1MODELCOOLINGMODELELECTRI

Page 12 - HEATING PERFORMANCE DATA

279104-YTG-B-0307Unitary Products Group 5* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.**Refer to Quick Selection

Page 13

279104-YTG-B-03076 Unitary Products GroupCOP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the t

Page 14

279104-YTG-B-0307Unitary Products Group 7ACCESSORIESRefer to Price Manual for specific model numbers.Start Assist Kit (2SA067*)Blower Time Delay - Av

Page 15

279104-YTG-B-03078 Unitary Products GroupTYPICAL FIELD WIRING - 3 PH (036 - 060)TYPICAL FIELD WIRING - 3 PH (090)THERMOSTATINDOOR UNITOUTDOOR UNITLOW

Page 16 - Group Drive 73069

279104-YTG-B-0307Unitary Products Group 9Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb temperatures diffe

Comments to this Manuals