High Static Pressure Blower
MBC-MBH 25 to 65
R407C
41
E-COM-M0615
Technical features
Options / Accessories
Sizes 25P 35P 45P 55P 65P
Square wired remote control O AMR03P
Square wired remote control
O AMR04P
with 7 days timer
Condensate pump A AMP01C AMP02B
PCB link A 625T300012-000
Wall mounting kit A AMW50A
Floor mounting kit A AMF44B
Low ambient kit for MOC O 625T20003-000
Low ambient kit for MOH O 625T20003-000 + 024T05052-000
Electric heater A Contact YORK
Discharge plenum A Contact YORK
O= option (factory fitted) A= accessory (supplied loose)
MBC - MBH
Models Sizes 25P 35P 45P 55P 65P
Cooling capacity kW 6.5 9.1 12.5 13.7 15.0
Heating capacity kW 6.7 9.3 11.7 13.9 17.2
Compressor Type Rotary Scroll
Refrigerant R407C
Power supply V/Ph/Hz 230 / 1 / 50 + E 400 / 3 / 50 + E + N
Power input kW 2.7 3.7 4.9 5.8 6.8
EER w/w 2.2 2.4 2.3 2.3 2.0
COP w/w 2.3 2.4 2.1 2.3 2.6
Fuse rating A 20 10 16 16 16
Indoor airflow m
3
/h 2 160 2 900 3 200 3 600 3 800
Available static pressure* Pa 130 150 170 200 180
Electric heater (in option for MBH) kW 2.5 4.5
Operating controls Wired
H (mm) 400 / 696 400 / 900 400 / 1 142 400 / 1 142 400 / 1 142
Dimensions Ind./Outd. W (mm) 718 / 850 924 / 1 060 1 204 / 1 060 1 204 / 1 060 1 404 / 1 060
D (mm) 616 / 287 616 / 345 616 / 345 616 / 345 616 / 345
Net weight
Indoor kg 39 44 50 52 60
Outdoor kg 69 108 122 127 130
Type of connection Flare
Piping
Diameter
Gas 5/8" 5/8" 3/4" 3/4" 3/4"
Liquid 3/8" 3/8" 3/8" 3/8" 3/8"
Refrigerant charge (c/o - h/p) g 2100 - 2100 3000 - 2500 3000 - 3000 4000 - 4000 4700 - 4700
Max pipe run m 25 25 30 30 30
Operating limits - cooling mode mini / maxi +19ºC (0ºC with low temperature kit (accessory) / +46ºC
Operating limits - heating mode mini / maxi -10ºC / +24ºC
* High speed at 80% of maximum airflow
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 7.5 m with initial charge