York YHJF18 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
510667-YTG-A-0409
Johnson Controls Unitary Products 7
\
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF18S41S1
MV12B FC/MC35B 18.0 3.76 1.40 11.0 2.48 1.30 8.50
MV12B FC/MC43B 18.0 3.90 1.35 10.9 2.56 1.25 8.50
YHJF24S41S1
MV12B FC/MC35B 22.2 3.68 1.77 14.9 2.46 1.77 8.50
MV12B FC/MC43B 22.2 3.82 1.70 14.9 2.54 1.72 8.50
YHJF30S41S1
MV12B FC/MC43B 30.0 3.88 2.27 18.8 2.68 2.06 9.00
MV16C FC/MC43C 30.0 3.92 2.24 18.8 2.70 2.04 9.00
YHJF36S41S1
MV12B FC/MC43B 36.0 3.74 2.82 24.4 2.52 2.84 8.20
MV16C FC/MC43C 36.0 3.74 2.82 24.2 2.52 2.81 9.00
YHJF42S41S1 MV20D FC/MC62D 40.5 4.02 2.95 26.0 2.76 2.76 9.00
YHJF48S41S1 MV20D FC/MC62D 48.0 3.82 3.68 31.8 2.60 3.58 9.00
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YHJF18S41S1 AV*36 18.0 3.98 1.33 10.8 2.62 1.21 8.50
YHJF24S41S1 AV*36 22.0 3.70 1.74 14.8 2.50 1.73 8.50
YHJF30S41S1 AV*36 29.8 3.98 2.19 18.6 2.74 1.99 9.00
YHJF36S41S1 AV*36 36.0 3.78 2.79 24.2 2.54 2.79 9.00
14.5 SEER HP WITH AHP / SHP / AHX / F*FP
YHJF18S41S1 AHX30 18.0 3.88 1.36 10.9 2.52 1.27 8.50
YHJF24S41S1
AHX30 22.23.641.7913.72.421.668.50
F6FP030 22.23.641.7915.12.421.838.20
F6FP036 22.23.681.7715.02.461.798.50
AHX36 22.43.701.7715.12.461.808.50
YHJF30S41S1
AHX36 30.04.002.2018.72.761.999.00
F6FP042 30.04.002.2018.72.761.999.00
YHJF36S41S1
AHX36 36.03.822.7624.22.562.779.00
AHX42 36.03.842.7522.22.562.549.00
F6FP042 36.03.882.7224.42.602.759.00
YHJF42S41S1
AHX60 40.54.002.9726.02.742.789.00
F6FP060 41.04.042.9726.22.742.809.00
YHJF48S41S1
AHX60 48.03.823.6831.62.603.569.00
F6FP060 48.03.823.6831.62.603.569.00
See notes below.
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF COP @ 47
47 OD 17 OD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF60S41S1 MV20D FC/MC62D
1 1160 43.0
2 1855 57.0 40.5 9.00 3.66
2 1160 54.9 39.0 8.85 3.04
14.5 SEER HP WITH AHX
YHJF60S41S1 AHX60
1 1160 43.1
2 1855 58.0 40.0 9.00 3.72
2 1170 57.5 40.0 8.90 3.24
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.