TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER – R-410A – 1 PHASE
MODELS:
YCJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
LISTED
561908-YTG-A-0410
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
Protected Compressor - The compressor is internally pro-
tected against high pressure, temperature, and externally by
a factory installed high pressure switch. This is accomplished
by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if
undesirable operating conditions occur. A liquid line filter-
drier further protects the compressor.
Durable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
Top Discharge - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - TECHNICAL GUIDE

TECHNICAL GUIDESPLIT-SYSTEM AIR CONDITIONERS13 SEER – R-410A – 1 PHASEMODELS:YCJD18 THRU 60(1.5 THRU 5 NOMINAL TONS)Due to continuous product improvem

Page 2 - Physical and Electrical Data

561908-YTG-A-041010 Johnson Controls Unitary ProductsYCJD48S41S3(H)T*9X*C20 FC/PC60C 21 1625 47.0 34.6 13.40 11.00T*9X*D20 FC/MC/PC60D 24 1490 47.5 33

Page 3

561908-YTG-A-0410Johnson Controls Unitary Products 11ACCESSORIESRefer to Price Manual for specific model numbers.Off Cycle Timer Delay - Provides a 5-

Page 4

561908-YTG-A-041012 Johnson Controls Unitary ProductsMultipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 5

561908-YTG-A-0410Johnson Controls Unitary Products 13Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 6

561908-YTG-A-041014 Johnson Controls Unitary ProductsMultipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 7

561908-YTG-A-0410Johnson Controls Unitary Products 15Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 8

561908-YTG-A-041016 Johnson Controls Unitary ProductsMultipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 9

561908-YTG-A-0410Johnson Controls Unitary Products 17Multipliers for determining the performance with other indoor sections.NOTE: For dry bulb tempera

Page 10 - 561908-YTG-A-0410

Subject to change without notice. Published in U.S.A. 561908-YTG-A-0410Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: 36

Page 11 - TYPICAL FIELD WIRING

561908-YTG-A-04102 Johnson Controls Unitary ProductsAll dimensions are in inches. They are subject to change with-out notice. Certified dimensions wil

Page 12 - COOLING PERFORMANCE DATA

561908-YTG-A-0410Johnson Controls Unitary Products 3PROCEDURES:1. Unit factory charge listed on the unit nameplate includes refrigerant for the conden

Page 13

561908-YTG-A-04104 Johnson Controls Unitary ProductsCOOLING CAPACITY - With Air Handler CoilsUNITMODELAIR HANDLERCOILMODEL1COOLINGMODEL WRATEDCFMNET M

Page 14

561908-YTG-A-0410Johnson Controls Unitary Products 5— = Not applicable.13 SEER AC WITH AHP / SHP / AHX / F*FPYCJD18S41S3(H)AHP18 17 – 650 17.5 12.9 1

Page 15

561908-YTG-A-04106 Johnson Controls Unitary ProductsCOOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and CoilsUNIT MODELFURNACE**COILMODE

Page 16

561908-YTG-A-0410Johnson Controls Unitary Products 7COOLING CAPACITY - With High Efficiency Motor FurnacesMODELSFURNACE MODELCOILMODEL1WCOOLINGRATED C

Page 17

561908-YTG-A-04108 Johnson Controls Unitary ProductsYCJD30S41S3(H)T*9X*C20 FC/MC/PC43C 21 720 28.2 19.3 14.00 12.00(Y*(8,L)C/T*8V)*A12 FC/MC/PC32A 14

Page 18

561908-YTG-A-0410Johnson Controls Unitary Products 9YCJD36S41S3(H)(Y*(8,L)C/T*8V)*C20 HC42 21 1190 35.6 25.6 14.00 12.00 (Y*9C/T*9V)*C16 HC42 21