York H*DB012-76 Installation Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
®
550.38-N1Y
10
Unitary Products Group
FIGURE 8 :
TYPICAL SINGLE PHASE FIELD WIRING
FIGURE 9 :
TYPICAL THREE PHASE FIELD WIRING
C
YRGW
WGR
Y
CONTACTOR
TERM INALS
FURNACE OR AIR HANDLER TERM INAL BLOCK
POW ER
CONTROL
FACTO RY
ROOM THERMOSTAT
*
* T e rm in a l W is o n ly
required on system s
w ith h e a t.
POW ER W IRING
208/230-1-60
2 3 0 -1 -5 0
COIL
ALL FIELD W IRING TO BE IN ACCORDANCE W ITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES
ALL OUTDOOR W IRING M UST BE W EATHERPROOF. USE COPPER CONDUCTORS ONLY.
24 VO LT C O N TR O L W IR IN G
Minimum 18 GA. Wire
(N E C C la s s 2 )
GROUND.
LUG
C
YRGW
WGR
Y
CONTACTOR
TERM INALS
FURNACE OR AIR HANDLER TERM INAL BLOCK
POW ER
CONTROL
FACTO RY
ROOM THERMOSTAT
*
* T e rm in a l W is
only required
on system s
w ith heat.
POW ER W IRING
208/230-3-60
460-3-60
380/415-3-50
COIL
GROUND
SCREW
ALL FIELD W IRING TO BE IN ACCORDANCE W ITH NATIONAL ELECTRICAL CODE (NEC) AND/OR LOCAL CODES
A L L O U T D O O R W IR IN G M U S T B E W E A T H E R P R O O F . U S E C O P P E R C O NDUCTORS ONLY.
24 VO LT C O N TR O L W IR IN G
M inim um 18 G A. W ire
(N E C C lass 2)
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments